422 research outputs found

    An exponential integration generalized multiscale finite element method for parabolic problems

    Get PDF
    We consider linear and semilinear parabolic problems posed in high-contrast multiscale media in two dimensions. The presence of high-contrast multiscale media adversely affects the accuracy, stability, and overall efficiency of numerical approximations such as finite elements in space combined with some time integrator. In many cases, implementing time discretizations such as finite differences or exponential integrators may be impractical because each time iteration needs the computation of matrix operators involving very large and ill-conditioned sparse matrices. Here, we propose an efficient Generalized Multiscale Finite Element Method (GMsFEM) that is robust against the high-contrast diffusion coefficient. We combine GMsFEM with exponential integration in time to obtain a good approximation of the final time solution. Our approach is efficient and practical because it computes matrix functions of small matrices given by the GMsFEM method. We present representative numerical experiments that show the advantages of combining exponential integration and GMsFEM approximations. The constructions and methods developed here can be easily adapted to three-dimensional domains

    Plasma levels of leukotriene B4 during hepatic allograft rejection

    Get PDF
    At the present time, rejection is the most frequent cause of graft dysfunction in liver transplantation. Differential diagnosis between this and other possible causes of dysfunction—preservation injury, vascular, biliary, viral—may well be difficult, as the clinical and analytical findings are often similar; moreover, no markers specific to rejection are available, and histological studies are necessary for a definitive diagnosis. For this reason, markers indicating activity within the immune system need to be established so as to provide a more specific means of distinguishing rejection from other causes of graft dysfunction. The immune response to an allograft is complex, and the intricate mechanisms regulating it are still not entirely understood. Nevertheless, several specialists have drawn connections among changes in the lymphocyte subpopulations, rises in the interleukin-2 levels, expression of the interleukin-2 receptor, and alteration in the expression of antigens belonging to class II in the greater complex of histocompatibility, with rejection of the allograft. Leukotriene B4 (LTB4) is a derivative of the metabolism of arachidonic acid via 5- lipoxygenase, whose in vitro behaviour is to encourage rejection by favoring leukocyte aggregation, proliferation of T lymphocytes, interleukin-1 and -2 secretion, and the development of "natural killer" cell subpopulations. This study examines the role of LTB4 in mediating the immune response to the hepatic allograft in order to assess its usefulness in early diagnosis of rejection

    Evaluation of PCR and indirect enzyme-linked immunosorbent assay on milk samples for diagnosis of brucellosis in dairy cattle

    Get PDF
    A study was performed to evaluate the previously described PCR (C. Romero, C. Gamazo, M. Pardo, and I. López-Goñi, J. Clin. Microbiol. 33:615-617, 1995) for the diagnosis of brucellosis in dairy cattle. Milk samples from 56 Brucella milk culture-positive cattle and from 37 cattle from Brucella-free herds were examined for Brucella DNA by PCR and for specific antibodies by an indirect enzyme-linked immunosorbent assay (ELISA). The specificities of both tests were 100% when testing the milk samples from Brucella-free cattle. The milk samples from 49 infected cattle were positive by PCR (87.5% sensitivity), and 55 were positive by ELISA (98.2% sensitivity). A PCR-positive sample was negative by ELISA, and 7 ELISA-positive samples were PCR negative, yielding an observed proportion of agreement of 0.91 for the two tests. Although the results suggest that ELISA is a better screening test than PCR, the combined sensitivity of the two assays was 100%, and their simultaneous application could be more useful than one test alone for a rapid screening of brucellosis in dairy cattle

    Fine synchronization of the CMS muon drift-tube local trigger using cosmic rays

    Get PDF
    33 páginas, 12 figuras.-- Open Access.-- CMS Collaboration: et al.The CMS experiment uses self-triggering arrays of drift tubes in the barrel muon trigger to perform the identification of the correct bunch crossing. The identification is unique only if the trigger chain is correctly synchronized. In this paper, the synchronization performed during an extended cosmic ray run is described and the results are reported. The random arrival time of cosmic ray muons allowed several synchronization aspects to be studied and a simple method for the fine synchronization of the Drift Tube Local Trigger at LHC to be developed.Individuals have received support from the Marie-Curie IEF program (European Union); the Leventis Foundation; the A. P. Sloan Foundation; and the Alexander von Humboldt Foundation.Peer reviewe

    Performance of the CMS Level-1 trigger during commissioning with cosmic ray muons and LHC beams

    Get PDF
    52 páginas, 25 figuras.-- Open Access.-- CMS Collaboration: et al.The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected.Acknowledge support from: FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA). Individuals have received support from the Marie-Curie IEF program (European Union); the Leventis Foundation; the A. P. Sloan Foundation; and the Alexander von Humboldt Foundation.Peer reviewe

    Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons

    Get PDF
    46 páginas, 17 figuras, 8 tablas.-- Open Access.-- CMS Collaboration: et al.During autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.Individuals have received support from the Marie-Curie IEF program (European Union); the Leventis Foundation; the A. P. Sloan Foundation; and the Alexander von Humboldt Foundation.Peer reviewe

    Alignment of the CMS muon system with cosmic-ray and beam-halo muons

    Get PDF
    43 páginas, 11 figuras, 6 tablas.-- Open Access.-- CMS Collaboration: et al.The CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.Individuals have received support from the Marie-Curie IEF program (European Union); the Leventis Foundation; the A. P. Sloan Foundation; and the Alexander von Humboldt Foundation.Peer reviewe

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    42 páginas, 15 figuras, 3 tablas.-- Open Access.-- CMS Collaboration: et al.The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3–4 microns RMS in the barrel and 3–14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.Individuals have received support from the Marie-Curie IEF program (European Union); the Leventis Foundation; the A. P. Sloan Foundation; and the Alexander von Humboldt Foundation.Peer reviewe
    corecore